1-1/2″-300LB-BW Cryogenic Bellows Seal Globe Valve
Description
Technical Datasheet
Product Name: Cryogenic Bellows Seal Globe Valve
Model: 1-1/2″-300LB BW Cryogenic Bellows Seal Globe Valve
1. General Information
| Item | Specification |
|---|---|
| Valve Type | Globe Valve (OS&Y, Rising Stem) |
| Nominal Size | 1-1/2 inches (DN40) |
| Pressure Rating | Class 300 |
| Connection Type | Butt Weld (BW) Ends |
| Special Design | Bellows Seal + Cryogenic Service (Extended Bonnet) |
| Body / Bonnet Material | Stainless Steel (Typically CF8/304 or CF8M/316) For cryogenic service |
| Operation | Handwheel (Manual) / Gearbox optional |
2. Technical Specifications
| Item | Specification |
|---|---|
| Pressure Rating | Class 300 (PN50) |
| Shell Test Pressure | 7.5 MPa (approx. 1110 psi) |
| Seal Test Pressure | 5.5 MPa (approx. 800 psi) |
| Design Temperature | -196°C to +150°C (Suitable for LNG, LPG, Liquid Nitrogen, Oxygen, etc.) |
| Applicable Media | Cryogenic Fluids: LNG (Liquefied Natural Gas), LPG, Liquid Oxygen, Liquid Nitrogen, Ethylene, etc. |
| Bonnet Type | Extended Bonnet (Long neck design to protect packing from freezing and ensure proper stem sealing) |
3. Main Material of Parts
| Part Name | Material | Material Grade (Reference) |
|---|---|---|
| Body | Stainless Steel | ASTM A351 CF8 (304) or CF8M (316) |
| Bonnet (Extended) | Stainless Steel | ASTM A351 CF8 (304) or CF8M (316) |
| Disc / Plug | Stainless Steel + Hard-facing | 304 / 316 + Stellite 6 (or 17-4PH optional) |
| Stem | Stainless Steel | ASTM A276 304 / 316 / 17-4PH |
| Bellows Assembly | Stainless Steel | ASTM A240 304 / 316L (Multi-ply, fully welded) |
| Seat Ring (Sealing) | Stainless Steel / Hard-facing | 304 / 316 / Stellite (Integral or welded) |
| Gland Packing | Low-Temperature Graphite / PTFE | – |
| Gasket | Spiral Wound | 304SS + Flexible Graphite |
| Handwheel | Cast Iron / Carbon Steel | – |
4. Main Dimensions & Connection Data (Unit: mm)
Note: Butt weld ends conform to ASME B16.25.
| Size (NPS) | End Type | Wall Thickness Schedule | Face to Face (End to End) (L) | Extended Bonnet Height (H) approx. | Handwheel Dia (W) approx. |
|---|---|---|---|---|---|
| 1-1/2″ (DN40) | Butt Weld (BW) | Schedule 40 / 80 (as per order) | ASME B16.10: 247 mm (Typical) | Varies by design (Long neck for cryogenic insulation) | Varies by design |
Note: Dimensions above are typical. Extended bonnet height is designed to accommodate insulation thickness and protect packing from low temperatures.
5. Applicable Design Standards
-
Design & Manufacture: BS 6364 (Specification for Valves for Cryogenic Service) / API 623 (Globe Valves) / ASME B16.34
-
Face-to-Face Dimensions: ASME B16.10
-
End Connections: ASME B16.25 (Butt Weld Ends)
-
Pressure-Temperature Rating: ASME B16.34
-
Inspection & Testing: BS 6364 / API 598 (Cryogenic testing at -196°C required)
-
Bellows Design: ISO 15761 / BS 6364
6. Product Features
-
Cryogenic Service Design: Compliant with BS 6364, specifically engineered for low-temperature applications down to -196°C.
-
Extended Bonnet: Long neck design isolates the packing gland from the cryogenic media, ensuring packing remains at ambient temperature for reliable sealing and preventing ice formation on the stem.
-
Bellows Seal: Fully welded stainless steel bellows provides a hermetic seal, eliminating fugitive emissions and ensuring zero stem leakage—critical for cryogenic and hazardous media.
-
Hardened Trim: Stellite hard-facing on seat and disc surfaces provides excellent wear resistance and tight shut-off under cryogenic conditions.
-
Butt Weld Ends: Provides a permanent, leak-free connection suitable for high-integrity cryogenic piping systems.
-
Drip Ring / Frost Break: Typically provided at the bottom of the extended bonnet to prevent condensation from reaching the valve body insulation.
-
Cryogenic Testing: Valves are 100% tested with liquid nitrogen at -196°C to verify seat and shell integrity under actual service conditions.
Remarks:
-
Material Selection: For cryogenic service, austenitic stainless steel (CF8/304 or CF8M/316) is mandatory due to its ductility and impact resistance at low temperatures. Carbon steel is notsuitable for cryogenic applications.
-
Cryogenic Testing: Confirm with the manufacturer that cryogenic testing (BS 6364) is included as part of the inspection and test plan.
-
Insulation: The extended bonnet length should accommodate the required insulation thickness for the specific cryogenic application.
-
For specific dimensional data and torque values, please refer to the official certified drawings from the manufacturer.