Standard Y Strainer
Description
Technical Data Sheet
Y-Type Strainer – Flanged – Ductile Iron – Stainless Steel Mesh
Product Name: Flanged Y-Type Strainer
Model No.: SY4 / SY14 (Example models for reference)
1. General Information
| Item | Specification |
|---|---|
| Product Type | Y-Type Pipeline Strainer (T-Type / Angle Pattern) |
| Body Material | Ductile Iron (ASTM A536, 65-45-12 / GGG-50) |
| Filter Element Material | Stainless Steel (SS304 / SS316) Perforated or Wire Mesh |
| Connection Type | Flanged Ends |
| Size Range | DN50 ~ DN300 (2″ ~ 12″) |
| Pressure Rating | PN10 / PN16 / Class 125 / Class 150 |
| Application | Water, Wastewater, Oil, Gas, and General Industrial Pipelines |
| Operation | Continuous filtration with periodic blow-off |
2. Design Standards & Specifications
| Item | Standard |
|---|---|
| Design & Manufacturing | GB/T 14382, MSS SP-70, BS 5152 |
| Face-to-Face Dimensions | Manufacturer’s standard (short or long pattern) |
| Flange Dimensions | ASME B16.5 (Class 150), EN 1092-2 (PN10/16), or GB/T 17241.6 |
| Pressure Testing | API 598 / EN 12266-1 |
| Screen Perforation | GB/T 5330 or ISO 4783 |
3. Main Component Materials
| Part Name | Material Specification | Remarks |
|---|---|---|
| Body | Ductile Iron (GGG-50 / 65-45-12) | Fusion bonded epoxy coated (FBE) or painted |
| Cover / Bonnet | Ductile Iron (GGG-50) | Includes gasket seal |
| Filter Screen (Mesh) | Stainless Steel SS304 / SS316 | Perforated or woven wire mesh |
| Gasket | Compressed Non-Asbestos Fiber (CNAF) / PTFE | Between body and cover |
| Drain / Blow-off Plug | Carbon Steel / Stainless Steel | At bottom of strainer for cleaning |
| Boltwork | Carbon Steel Zinc Plated / Stainless Steel | Cover bolts |
4. Filter Mesh Specifications
| Item | Standard Option | Fine Filtration Option |
|---|---|---|
| Screen Type | Perforated Stainless Steel | Woven Stainless Steel Wire Mesh |
| Mesh Size / Perforation | 1.0 mm – 3.0 mm diameter holes | 10 mesh – 100 mesh (as required) |
| Open Area Ratio | ≥ 50% | ≥ 40% |
| Material Grade | SS304 / SS316 | SS304 / SS316 |
| Retention Rating | Coarse (800–3000 microns) | Medium to Fine (150–2000 microns) |
5. Technical Parameters & Dimensions (Reference)
Flange Drilling: PN16 / Class 150
| Nominal Size (DN) | Length (L) mm | Height (H) mm | Flange O/D (D) mm | Bolt Circle (D1) mm | Flange Thickness (t) mm | No. of Bolt Holes | Weight (kg) |
|---|---|---|---|---|---|---|---|
| DN50 (2″) | 230 | 140 | 165 | 125 | 19 | 4 | 8 |
| DN65 (2.5″) | 290 | 165 | 185 | 145 | 19 | 4 | 11 |
| DN80 (3″) | 310 | 175 | 200 | 160 | 20 | 8 | 14 |
| DN100 (4″) | 350 | 215 | 220 | 180 | 20 | 8 | 20 |
| DN125 (5″) | 400 | 245 | 250 | 210 | 22 | 8 | 27 |
| DN150 (6″) | 480 | 280 | 285 | 240 | 22 | 8 | 35 |
| DN200 (8″) | 600 | 350 | 340 | 295 | 24 | 12 | 55 |
| DN250 (10″) | 730 | 430 | 405 | 355 | 26 | 12 | 80 |
| DN300 (12″) | 850 | 510 | 460 | 410 | 26 | 12 | 110 |
Note: Dimensions are for reference only. Actual dimensions may vary by manufacturer.
6. Testing & Inspection
| Test Item | Test Pressure (PN16) | Acceptance Criteria |
|---|---|---|
| Shell Hydrostatic Test | 1.5 × PN = 24 bar | No visible leakage, no structural damage |
| Seat / Body Seal Test | 1.1 × PN = 17.6 bar | No leakage through cover gasket or drain plug |
| Air Test (Optional) | 0.6 bar (6 bar optional) | Soap bubble test for leak detection |
| Screen Integrity | Visual / Pass | No tears, correct mesh size installed |
7. Features & Options
-
Ductile Iron Body: Higher strength and impact resistance compared to gray cast iron.
-
Stainless Steel Screen: Corrosion-resistant, easy to clean, and replaceable.
-
Flanged Connections: Easy installation and removal from pipeline.
-
Bottom Drain / Blow-off Connection: Allows purging of debris without removing the screen (threaded plug or flanged outlet optional).
-
Coating: Fusion Bonded Epoxy (FBE) or solvent-free epoxy for corrosion protection (optional).
-
Screen Options:
-
Perforated screen (standard for coarse filtration).
-
Wire mesh lined screen (for finer filtration).
-
Dual-element screens available upon request.
-
-
Magnetic Insert: Optional magnetic rod to capture ferrous particles.
8. Installation & Maintenance Notes
-
Install with the screen chamber pointing vertically downward for easy cleaning.
-
Flow direction must match the arrow on the body.
-
Provide adequate space below the strainer for screen removal.
-
Regularly open the blow-off valve or remove the screen for cleaning, depending on the debris load.
-
Check gasket condition during screen maintenance and replace if necessary.
Note: This data sheet provides general specifications. For specific projects, please refer to the manufacturer’s final drawings and parameters.