Wafer Check Valve (Single Disc / Swing Type)
Description
TECHNICAL DATA SHEET
Product: Wafer Check Valve (Single Disc / Swing Type)
Model Designation: CF8 Stainless Steel, Lifting Eye Version
Nominal Sizes Covered: DN50, DN65, DN80
Document Ref: TDS-WCV-CF8-LE
1. Product Overview
Wafer-type non-return valve with a single swing disc, investment-cast CF8 (SS304) body, and an integral lifting eye. Designed for compact installation between flanges in horizontal or vertical pipelines with upward flow. The valve closes by gravity and back-pressure; a spring return is optional upon request. Typical service includes water, seawater, steam, and compatible chemical media where SS304 corrosion resistance is adequate.
2. Design & Applicable Standards
-
Design: API 594 Type A (short face-to-face wafer pattern) ; alternatively DIN/EN wafer swing check valve construction.
-
Face-to-Face: API 594 Type A or EN 558-1 Series 16 (short pattern) .
-
Flange Compatibility: PN10/16 per EN 1092-1; Class 125/150 per ASME B16.1/B16.2 (upon request).
-
Pressure Testing: API 598 (shell test and seat leakage test) .
-
Marking: Manufacturer name/logo, size (DN), pressure rating (PN), body material (CF8), and heat number.
3. Material of Construction
| No. | Part | Material | Standard / Grade |
|---|---|---|---|
| 1 | Body | Stainless Steel | CF8 (SS304 / 1.4308) |
| 2 | Disc | Stainless Steel | CF8 |
| 3 | Seat / Seal Ring | Elastomer | EPDM (standard) / Viton (FKM) optional |
| 4 | Lifting Eye (Eye Bolt) | Stainless Steel | 304 (SS304) |
| 5 | Hinge Pin / Fasteners | Stainless Steel | 304 |
| 6 | Body O-Ring (flange sealing) | Elastomer | EPDM (standard) |
The lifting eye is an integral 304 stainless steel eye bolt screwed into the body, used for safe handling and installation; it is not intended for permanent load support of the connected piping.
4. Pressure–Temperature Ratings
| Rating | Value |
|---|---|
| Nominal Pressure (PN) | PN16 (16 bar / 232 psi) |
| Max. Operating Pressure | 16 bar at ambient temperature |
| Operating Temperature Range | −10 °C to +180 °C (Viton seat) ; −20 °C to +120 °C (EPDM seat, typical) |
| Shell Test Pressure (API 598) | 1.5 × nominal pressure (24 bar for PN16) |
| Seat Leakage Test | Per API 598 acceptable leakage rates |
For temperatures above 120 °C, confirm seat material compatibility. CF8 (SS304) retains adequate strength across the stated range; however, chloride-containing media require attention to stress-corrosion cracking risk.
5. Dimensions & Weights (Reference, PN16)
| Size | DN | NPS | Face-to-Face L (mm) | Body OD ØD (mm) | Overall Height with Eye (approx., mm) | Weight (approx., kg) |
|---|---|---|---|---|---|---|
| DN50 | 50 | 2″ | 43 | 101–104 | 180–200 | 1.5–1.8 |
| DN65 | 65 | 2½” | 46 | 121–125 | 195–215 | 2.1–2.5 |
| DN80 | 80 | 3″ | 64 | 134–140 | 215–235 | 2.8–3.3 |
Face-to-face “L” values conform to API 594 Type A / EN 558 Series 16 short pattern. ØD is the flange-locating diameter; final dimensions depend on the specific flange drilling standard. Eye height varies slightly by size; refer to the manufacturer’s certified drawing for installation clearance.
6. Inspection & Testing
Each valve is routinely subjected to:
-
Shell test — hydrostatic pressure applied inside the assembled valve with ends closed, valve partially open; no leakage through the body wall or joints.
-
Seat leakage test — pressure applied to the downstream side; leakage shall not exceed API 598 limits for metal-seated or soft-seated check valves.
-
Visual and dimensional inspection — casting integrity, machining finish, face-to-face dimension, and lifting-eye thread engagement.
Test certificates (hydrostatic and material) can be supplied upon request.
7. Installation & Operating Notes
-
Install between flanges with gaskets compatible with the sealing elastomer. Ensure sufficient pipe support; the lifting eye is for valve handling only.
-
Preferred orientation: horizontal line with vertical disc lift, or vertical line with upward flow.
-
The valve relies on flow reversal for closure. In services prone to water hammer or low-pressure reverse flow, a spring-loaded disc variant is recommended.
-
Not suitable for severe slurry or high-solids media without prior consultation; CF8 is not intended for strong oxidizing acids or hot concentrated chlorides.
8. Optional Variants
-
Seat material: Viton (FKM) for elevated temperature and chemical resistance; EPDM for hot water and steam.
-
Spring-loaded disc for rapid closure and any-orientation installation.
-
Alternative body material: CF8M (SS316) for enhanced chloride resistance.
-