Flanged Ball Check Valve
Description
Technical Data Sheet — Flanged Ball Check Valve
1. Product Description
The flanged ball check valve is a non-return valve featuring a ductile iron body and a rubber-coated ball. The valve opens by the thrust of the flowing medium and closes by the ball’s own weight and reverse flow pressure, providing reliable backflow prevention. Its simple design with a smooth, full-bore flow passage makes it particularly suitable for media containing suspended solids such as sewage and slurry, and it is not prone to clogging or jamming.
The valve has no shafts, pins, or springs in the internal mechanism, reducing potential failure points and making maintenance simple. It is suitable for both horizontal and vertical installation (vertical installation requires upward flow direction).
2. General Specifications
| Parameter | Specification |
|---|---|
| Product Type | Flanged Ball Check Valve (Non-Return Valve) |
| Nominal Diameter (DN) | DN100 |
| Nominal Pressure (PN) | PN16 (1.6 MPa / 16 bar) |
| Body Material | Ductile Iron QT450-10 (EN-GJS-450-10) |
| Connection Type | Flanged (EN 1092-2 / GB/T 17241.6) |
| Installation Orientation | Horizontal or Vertical (flow must be upward) |
| Design Standard | BS EN 1074-3 / EN 12334 |
| Face-to-Face Standard | EN 558-1, Series 48 (DIN 3202 F6) |
| Marking Standard | EN 19 |
| Testing Standard | EN 12266 (100% tested) |
3. Materials of Construction
| No. | Component | Material Specification |
|---|---|---|
| 1 | Body | Ductile Iron QT450-10 / EN-GJS-450-10 |
| 2 | Cover (Bonnet) | Ductile Iron QT450-10 / EN-GJS-450-10 |
| 3 | Ball | NBR-coated rubber (solid rubber or steel core with rubber lining) |
| 4 | Seat Sealing Face | Integral with body; metal-to-rubber soft sealing |
| 5 | Fasteners (Bolts/Nuts) | Zinc-plated carbon steel / Stainless steel Grade 8.8 / A2-70 |
| 6 | Cover Gasket | Non-asbestos fiber sheet / EPDM |
| 7 | Surface Coating | Internal and external epoxy coating |
4. Technical Parameters
| Parameter | Value |
|---|---|
| Nominal Pressure | PN16 (1.6 MPa / 16 bar) |
| Shell Test Pressure | 1.5 × PN (2.4 MPa) |
| Seat Test Pressure | 1.1 × PN (1.76 MPa) |
| Working Temperature (NBR) | -20°C to +80°C |
| Working Temperature (EPDM) | -10°C to +80°C |
| Suitable Media | Clean water, sewage, seawater, slurries with particles, weak acid/alkali solutions |
| Flow Passage | Full bore design |
| Head Loss | Low (full bore, low cracking pressure) |
5. Dimensions — DN100 (PN10/PN16)
| Parameter | Value |
|---|---|
| Nominal Diameter | DN100 |
| Face-to-Face Length (L) | 300 mm |
| Flange Outer Diameter (D) | 220 mm |
| Bolt Circle Diameter (K) | 180 mm |
| Number of Bolt Holes | 8 |
| Bolt Hole Diameter | 8-Φ19 mm |
| Approximate Height (H) | 210 mm |
| Approximate Weight | 35 kg |
6. Flow Characteristics
| Parameter | Value (DN100) |
|---|---|
| Flow Coefficient Kv | 384 m³/h (at 1 bar head loss, 20°C) |
Note: Kv value may vary slightly by manufacturer. Contact the supplier for precise flow verification.
7. Standards & Compliance
| Standard | Description |
|---|---|
| EN 12334 | Cast iron check valves — requirements for flanged end connections, DN40 to DN1000, PN6 to PN40 |
| EN 558-1 Series 48 | Face-to-face dimensions |
| EN 1092-2 | Flange drillings, PN10/PN16 |
| EN 12266 | Pressure testing of valves |
| ISO 5752 | Face-to-face dimensions (international equivalent) |
| GB/T 17241.6 | Flange standard (China equivalent) |
8. Key Features
-
Full bore design — smooth flow passage with minimal head loss
-
Self-cleaning — ball rotates during operation, preventing impurities from getting stuck
-
Low cracking pressure — operates effectively at low differential pressure
-
Easy maintenance — removable bonnet for ball inspection or replacement without removing the valve from the pipeline
-
No moving mechanical parts — no shafts, pins, or springs, reducing wear and failure points
-
Epoxy coating — internal and external anti-corrosion protection
-
Versatile installation — suitable for horizontal or vertical (upward flow) orientation
9. Applications
-
Water supply and distribution systems
-
Wastewater and sewage treatment plants
-
Pumping stations
-
HVAC systems
-
Industrial piping (petroleum, chemical, metallurgy)
-
Fire protection systems
-
Irrigation and agricultural systems
Notes:
-
The information in this data sheet is based on standard product specifications and industry-standard references. Actual dimensions and performance may vary slightly by manufacturer.
-
Please verify all parameters against the specific manufacturer’s documentation before installation or procurement.
-
Installation must be performed by qualified personnel in accordance with applicable local codes and standards.