Compact Pneumatic Diaphragm Single-Seat Control Valve (ZJHP-16K DN25)
Description
Technical Data Sheet: Compact Pneumatic Diaphragm Single-Seat Control Valve (ZJHP-16K DN25)
1. Product Overview
This product is a Compact Pneumatic Diaphragm Single-Seat Control Valve, model ZJHP-16K, with a nominal size of DN25, nominal pressure of PN16 (1.6 MPa), and a valve body made of CF8 (304 Stainless Steel). The valve consists of a multi-spring pneumatic diaphragm actuator and a low-flow-resistance straight-through single-seat valve body. It features a top-guided single-seat structure, offering a compact design, light weight, high flow capacity, excellent sealing performance, and reliable operation. The valve receives a standard 4-20mA DC electrical signal. Through an electro-pneumatic valve positioner, the electrical signal is converted into an air pressure signal to drive the valve plug, achieving precise regulation of flow, pressure, temperature, and liquid level in pipeline media.
This data sheet corresponds to the product nameplate markings: RUIGE Positioner, DN25, PN16, CF8 Body.
2. Technical Specifications
| Item | Parameter |
|---|---|
| Model | ZJHP-16K |
| Valve Type | Compact Pneumatic Diaphragm Single-Seat Control Valve |
| Nominal Size | DN25 |
| Nominal Pressure | PN16 (1.6 MPa) |
| Body Material | CF8 (304 Stainless Steel) |
| Trim Type | Unbalanced Single-Seat Plug |
| Connection Type | Flanged (RF) |
| Actuator | Multi-Spring Pneumatic Diaphragm Actuator |
| Positioner | RUIGE Electro-Pneumatic Valve Positioner, Input Signal: 4-20mA DC |
| Action Mode | Air-to-Close (FC, Fail Closed) / Air-to-Open (FO, Fail Open) Optional |
| Flow Characteristic | Linear / Equal Percentage |
| Inherent Rangeability | 50:1 |
| Allowable Leakage Class | Metal Seat: Class IV; Soft Seat: Class VI |
| Design Standard | GB/T 4213-2024 “Pneumatic Control Valves” |
3. Main Component Materials
| Component | Material | Standard / Grade |
|---|---|---|
| Body / Bonnet | Stainless Steel (Cast) | CF8 (304 SS) |
| Plug / Seat | Stainless Steel with Stellite Hardfacing | 304 SS + Stellite |
| Stem | Stainless Steel | 304 SS |
| Packing | V-type PTFE / Flexible Graphite | PTFE / Flexible Graphite |
| Gasket | Metal Jacketed Graphite Gasket | 316 SS + Graphite |
| Diaphragm | NBR with Reinforced Polyester Fabric | NBR |
| Diaphragm Casing | Carbon Steel | A3 |
| Positioner | Electro-Pneumatic Valve Positioner | RUIGE |
| Air Connection | — | M16×1.5 |
Note: The plug and seat are hardfaced with Stellite cobalt-based alloy, allowing for a smaller allowable leakage rate, down to 10⁻⁵ × rated valve capacity.
4. Main Technical Parameters
4.1 Valve Body Parameters
| Item | Parameter |
|---|---|
| Nominal Size | DN25 |
| Nominal Pressure | PN16 |
| Seat Diameter | 12 mm |
| Rated Flow Coefficient (Kv) | Equal Percentage: 2.5; Linear: 2.8 |
| Rated Travel | 16 mm |
| Effective Diaphragm Area | 350 cm² |
| Spring Range | 20~100 KPa (Standard) |
| Air Supply Pressure | 0.14 MPa (Standard) |
| Media Temperature | -40°C to +230°C (Standard Type) |
| Flange Standard | GB/T 9113 / JB/T79 |
Note: The ZJHP series offers nominal pressure ratings of PN10, 16, 40, and 64, with body sizes ranging from DN20 to DN200, and media temperature ranges from -200°C to +560°C.
4.2 Actuator Parameters
| Item | Parameter |
|---|---|
| Actuator Type | Multi-Spring Pneumatic Diaphragm Actuator |
| Effective Diaphragm Area | 350 cm² |
| Rated Travel | 16 mm |
| Spring Range | 20~100 KPa (Standard); 40~200 KPa (Optional) |
| Air Supply Pressure | 0.14 / 0.16 / 0.28 / 0.40 MPa |
| Air Connection | M16×1.5 |
| Action Mode | Air-to-Close (Reverse Acting, Fail Closed) / Air-to-Open (Direct Acting, Fail Open) |
4.3 Positioner Parameters
| Item | Parameter |
|---|---|
| Positioner Brand | RUIGE |
| Input Signal | 4~20 mA DC |
| Ambient Temperature | -20°C to +70°C |
| Basic Error | ±1.5% |
| Hysteresis | ≤1.5% |
| Dead Band | ≤0.6% |
| Terminal Point Deviation | ±2.5% |
5. Performance Specifications
In accordance with GB/T 4213-2024 “Pneumatic Control Valves”:
| Performance Item | Specification |
|---|---|
| Basic Error | ±1.5% |
| Hysteresis | ≤1.5% |
| Dead Band | ≤0.6% |
| Terminal Point Deviation | ±2.5% |
| Rated Travel Deviation | ≤2.5% |
| Allowable Leakage (Metal Seat) | Class IV (10⁻⁴ × Rated Valve Capacity) |
| Allowable Leakage (Soft Seat) | Class VI (Bubble-tight, Zero Leakage) |
| Inherent Rangeability | 50:1 |
Note: GB/T 4213-2024 “Pneumatic Control Valves” was implemented on July 1, 2025. It specifies product classification, technical requirements, test methods, and inspection rules for pneumatic control valves used in industrial process control systems.
6. Working Principle
The ZJHP pneumatic single-seat control valve can be classified into two action modes:
-
Air-to-Close (FC, Fail Closed): Equipped with a reverse-acting actuator. When the input signal pressure changes from the lower limit to the upper limit, the valve goes from fully closed to fully open. In the event of an air supply failure, the actuator spring closes the valve.
-
Air-to-Open (FO, Fail Open): Equipped with a direct-acting actuator. When the input signal pressure changes from the lower limit to the upper limit, the valve goes from fully open to fully closed. In the event of an air supply failure, the actuator spring opens the valve.
The positioner receives the 4-20mA DC current signal from the control system, converts it into an air pressure signal output, and drives the diaphragm actuator to generate thrust. This moves the valve stem and plug, thereby changing the valve opening and achieving precise regulation of the fluid medium.
7. Installation & Operation Instructions
-
Installation Orientation: The valve can be installed at any angle. It is recommended that the arrow on the valve body matches the media flow direction.
-
Straight Pipe Requirement: Leave straight pipe sections before and after the control valve, with a length of no less than 10 times the pipe diameter (10D), to avoid affecting flow characteristics due to excessively short straight pipe sections.
-
Environmental Conditions: The working environment temperature should be between -30°C and +60°C, with a relative humidity not exceeding 95%.
-
Pipe Cleaning: Thoroughly clean the piping system before installation to remove welding slag, debris, etc., to prevent damage to the seat sealing surface.
-
Air Supply Requirements: Ensure the air supply is clean and dry, and the air supply pressure is stable within the range of 0.14 to 0.40 MPa. The air pipe connection specification is M16×1.5.
-
Electrical Wiring: The positioner input signal is 4-20mA DC. Wiring must comply with explosion-proof requirements (if applicable).
-
Maintenance: Periodically check the positioner output pressure, stem movement flexibility, and packing sealing condition. To replace the packing, the valve must be removed from the pipeline and serviced by professionals.
8. Dimensional Reference
| Item | Value |
|---|---|
| Nominal Size | DN25 |
| Face-to-Face (L) | 184 mm (PN16 Flanged) |
| Body Height (H1) | 58 mm |
| Total Height (H, Standard Type) | Approx. 410 mm |
| Diaphragm Casing Diameter (ΦA) | 285 mm |
Note: Dimensions above are standard reference values for the ZJHP series PN16. Actual dimensions may vary; please refer to the manufacturer’s drawing.
9. Applications
-
Industrial process automatic control systems in petroleum, chemical, power, and metallurgy industries
-
Precise control of pressure, flow, temperature, and liquid level of gases and liquids
-
Particularly suitable for applications with small allowable leakage and low pressure differential across the valve
-
Automatic regulation of steam, water, oil, and corrosive media in pipeline systems
10. Ordering Information
Please provide the following information when ordering:
-
Product Model (ZJHP-16K)
-
Nominal Size (DN25 / DN50 / DN80, etc.)
-
Nominal Pressure (PN16 / PN40 / PN64, etc.)
-
Body Material (CF8 / CF8M / WCB, etc.)
-
Trim Material (304 SS / 316 SS + Stellite Hardfacing, etc.)
-
Flow Characteristic (Linear / Equal Percentage)
-
Action Mode (Air-to-Close FC / Air-to-Open FO)
-
Positioner Brand & Signal Type (4~20mA DC)
-
Media Name, Temperature, Pressure, and Flow Parameters
-
Special Requirements (Explosion-proof Grade, Coating Color, Certification Requirements, etc.)